CS6200 Series 2D Barcode Scanner User Manual Version: MD6_UM_EN_V1.1.5
6 Introduction to installation Note: If any of the below operation is incorrect, turn off the power immediately and check the scanner for any imprope
7 Installation - USB The scanner attaches directly to a USB host, and is powered by it. No additional power supply is required. 1.
8 Programming instruction Important notes: 1. During the process of programming, LED is lighting to indicate the programming correctness. LED wil
9 Operate the scanner by receiving command via UART Note: 1- The information in this chapter is provided for the scanner with RS232 cable or USB c
10 Interface selection This scanner supports interfaces such as keyboard wedge, RS-232 serial wedge, and USB interface. In most of the cases, simp
11 Keyboard wedge Keyboard type: As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. Keyboard lay
12 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting IBM AT, PS/2 00* * Keyboard type Apple Mac compatibles 01 USA
13 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 40ms 03 80ms 04 Alphabetic key 00* * Numeric keypad 01 Numer
14 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting
15 RS-232 interface Flow control: None-The communication only uses TxD and RxD signals without any hardware or software handshaking proto
i Warning: Ensure that the optional DC adapter works at +5V, especially for the RS-232 interface cable. NOTICE: 1. All software, including
16 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 80ms 05 00-99 Response delay 00-99 (100ms) 00* * 300 00 600
17 USB interface USB device type: HID keyboard– By setting, the scanner is used as a USB HID keyboard emulation device. The keyboard
18 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Denmark 07 Japanese 08 German 09 0ms 00 5ms 01* * 10ms 02
19 Hand-held scan & some global settings Scanning mode: Good-read off-The trigger button must be pressed once to activate scanning.
20 Printable character only- If this option is selected, the scanner will output the printable characters only, i.e. in ASCII from 20H to 7EH. Alphan
21 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 00-66 Global G1-G6 string selection 00-66 00* Disable 00 Ele
22 Indication Power on alert: After power-on the scanner will generate an alert signal to indicate a successful self-test. LED indication: After each
23 Decode illumination and decode aiming pattern Decode illumination mode: Enable illumination causes the scanner to turn on the illumina
24 DPM & 2D symbologies readability setting 2D symbologies read: A global setting of 2D symbologies readability. DPM format read: By setting Enab
25 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Follow respective 2D symbology setting 00* * All 2D OFF 01 All
ii Contents Technical specifications ...
26 Note: The instruction of calibrating the aimer in vertical centering direction. 1. Scan the barcode on this page. The scanner will giv
27 UPC-A Read: Format Leading zero Data digits (11 digits) Check digitCheck digit verification: The check digit is optional. Check digit trans.: By
28 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting None 00* * 2 digits 01 5 digits 02 Supplement digits 2 or 5
29 UPC-E Read: Format Leading zero Data digits (6 digits) Check digitsCheck digit verification: The check digit is optional and made as the sum of t
30 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 2 digits 01 5 digits 02 2 or 5 digits 03 None 00* * Truncat
31 UPC-E1 Read: Format Leading zero “1” Following 5 data digits Check digitsCheck digit verification: The check digit is optional and made as the s
32 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Disable 00 Read Enable 01* * Disable 00 Check digit verific
33 EAN-13 Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerica
34 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Disable 00 Read Enable 01* * Disable 00 Check digit verifi
35 EAN-8 Read: Format Data digits (7 digits) Check digitCheck digit verification: The check digit is optional and made as the sum of the numerical v
iii PDF417 ...
36 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00 Read Enable 01* * Disable 00 Check digit verifica
37 Code 39 Read: Format ⋆ Data digits (variable) Check digit (optional) ⋆Check digit verification: The check digit is optional and made as the sum
38 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00 Read Enable 01* * Disable 00* * Check digit verifi
39 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Enable 01 Disable 00* * Code 32 Prefix “A” transmission Enable
40 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module
41 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Disable 00 Read Enable 01* * Disable 00* * USS 01 Check di
42 Industrial 2 of 5 Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of Code 39. Code ID setting: Refer to
43 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 o
44 Codabar Read: Format Start Data digits (variable) Check digit (optional) End Check digit verification: The check digit is made as the sum modul
45 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 00-66 Insert group selection 00-66 00* * ABCD/ABCD 00* * abcd/a
1 Technical specifications Table 1-1 Technical specifications Input voltage 5 VDC ± 0.25V Power 1.60W (working); 0.40W (standby) Current 320mA (worki
46 Code 128 Read: Format Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum module 103 of all
47 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00 Read Enable 01* * Disable 00 Check digit verifica
48 ISBT 128 Read: Format “=” or “&” Data digits (variable) Check digit (optional)Check digit verification: The check digit is made as the sum mo
49 Code 93 Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The check digit is made as the sum module 47 of th
50 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional)Check digit verification: The check digit is presen
51 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00* * Read Enable 01 Disable 00 One digit 01* * Res
52 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey
53 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00* * Read Enable 01 Disable 00* * 1 digit (mod 10)
54 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional)Check digit verification: The UK/Plessey has one or two optional check di
55 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of
2 Cable connector pin-outs descriptions Cable connector interface pin-outs The pin-outs descriptions in Table 1 apply to the cable connector on the
56 Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Disable 00 Read Enable 01* * Disable 00 Check digit verific
57 China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of Code 39. The code length of China Post is 11.
58 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, exc
59 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion
60 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer
61 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the sy
62 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Only 6 converted to B 03 Only 7 converted to C 04 Only 8 converte
63 PDF417 Read: Format Data characters (variable) Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00 Read
64 MicroPDF417 Read: Format Data characters (variable) Multiple-scan setting Option bar code Option Alpha. entry Single-scan setting Disable 00
65 QR Code Read: Format Data characters (variable) Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00 Read
3 Default setting for each barcode Table 2 Default setting for each barcode Code type Read enable Check digit verification Check digit transmissionMi
66 Data Matrix Read: Format Data characters (variable) Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00
67 G1-G6 & FN1 substitution string setting Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code I
68 Testing barcode: FN1 substitution string setting: The FN1 character (0x1D) in an UCC/EAN128 barcode, or a Code 128 barcode, or a GS1 DataBar bar
69 Testing barcode: Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting 0-22 characters 00-FF16 Prefix string set
70 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting <SP> 20* * A un-defined character 00 1-22 defined charact
71 G1-G4 string position & Code ID position Format of barcode data transmission Prefix Code name Preamble Code ID Code length Code data Code
72 String transmission Note: The information in this chapter is closely related to the chapter of String setting. Format of barcode data transmission
73 Multiple-scan setting Option bar code Option Alpha. entrySingle-scan setting Disable 00* * Postamble transmission Enable 01 Disable 00* * P
74 Test Chart UPC-A UPC-E EAN-8 EAN-13 Code 39 Code 32 A908765439 Code 128 Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Read disabl
75 Test Chart (Continued) UCC/EAN 128 Code 11 (Default setting: Read disable) MSI/Plessey (Default setting: Read disable) UK/Plessey ISBN/ISS
4 Dimensions
76 Test Chart (Continued) PDF417 12=890ab-+%xyz MicroPDF417 23+-mdo QR code 1234567890ABCD-+()&*%^@#$!XYZ Data Matrix 123890abc-+=&*%^!
77 Maintenance Cleaning the exit window is the only maintenance required. A dirty window may affect scanning accuracy. 1. Do not all
78 ASCII Table for keyboard wedge for RS-232 H L 0 1 0 1 0 Null NUL DLE 1 Up F1 SOH DC1 2 Down F2 STX DC2 3 Left F3 ETX DC3 4 Righ
79 Barcode representing non-printable character Notes to make the following barcode: 1. According to different barcode printing software, the metho
80 Return default parameters & others WARNING: Default value initialization If you wish to return the scanner to all the factory default sett
81 Configuration alphanumeric entry barcode
5 Parts of the scanner Figure 1 ① LED ② Exit window ③ Trigger ④ Cable interface port ⑤ Release-hole of the cable ⑥ Beeper Figure 2 Remove th